| Model | Max. batch (kg) | Max. hourly capacity (t) | Main motor (CV-HP) | Aerators (CV-HP) | Cooling blower (CV-HP) |
|---|---|---|---|---|---|
| 100-270 | 2450 | 125 | 270 | 2 x 60 | 15 |
| 100-220 | 2300 | 110 | 220 | 2 x 50 | 15 |
| 85-220 | 1800 | 80 | 220 | 2 x 60 | 10 |
| 85-180 | 1650 | 72 | 180 | 2 x 40 | 10 |
| 75 | 1000 | 50 | 125 | 2 x 30 | 7,5 |
Batch capacity, hourly capacity and cycle times are approximate and depend upon sand formulation, degree of cooling desired and installation of moisture or compactability controller operating in real time.